== Manuals and user guides ==
[[Leica SP8 Liachroic intro|Introduction protocol]]
 
== Current status ==
The current status of the microscope can be found [[Current microscope status#Light microscopes|here]] and on the [https://bookings.science.ru.nl/category/general-instrumentation-gi/gi-light-microscopy-image-analysis booking website].
 
== Biosafety and access ==
The SP8-Lia is located in an AP-1 room. See the [[General Instrumentation Department#Biosafety|Biosafety]] section on rules regarding working in this room.
 
== Technical specifications ==
 
* Inverted DMi8 CS motorized microscope
* 2000 FOV scanner SP8
* Light source EL 6000
 
===Filter Cubes===
* DAPI LP (ex: 380-400, em: 425-infinite nm)
* GFP (ex: 450-490, em: 500-550)
* Y3 (ex: 533-558, em: 570-640)
* Y5 (ex: 590-650, em: 662-738)
===Objectives===
* Obj. HC PL APO 10x/0.40 CS2 (FWD = 2.56 mm)
* Obj. HC PL FLUOTAR L 20x/0.40 (7.5-6.2 mm)
* Obj. HC PL APO 20x/0.75 CS2 (0.66 mm)
* Obj. HC PL FLUOTAR L 40x/0.60 (3.3-1.9 mm)
* Obj. HC PL APO 40x/1.30 Oil CS2 (0.24 mm)
* Obj. HC PL APO 63x/1.40 OIL CS2 (0.14 mm)
===Detectors===
* 1 x PMT Detector
* 2 x HyD SP GaAsP Detector (sensitive)
* Brightfield detector for DMI
===Lasers===
* Laser 405 nm DMOD Compact
* Laser Blue 488 nm
* Laser Green 552 nm
* Laser Red 638 nm
===Camera===
* Leica DFC7000 GT monochrome camera
===Software===
* LAS X SP8 Control Software with Navigator Module

Latest revision as of 11:19, 29 September 2025

Manuals and user guides

Introduction protocol

Current status

The current status of the microscope can be found here and on the booking website.

Biosafety and access

The SP8-Lia is located in an AP-1 room. See the Biosafety section on rules regarding working in this room.

Technical specifications

  • Inverted DMi8 CS motorized microscope
  • 2000 FOV scanner SP8
  • Light source EL 6000

Filter Cubes

  • DAPI LP (ex: 380-400, em: 425-infinite nm)
  • GFP (ex: 450-490, em: 500-550)
  • Y3 (ex: 533-558, em: 570-640)
  • Y5 (ex: 590-650, em: 662-738)

Objectives

  • Obj. HC PL APO 10x/0.40 CS2 (FWD = 2.56 mm)
  • Obj. HC PL FLUOTAR L 20x/0.40 (7.5-6.2 mm)
  • Obj. HC PL APO 20x/0.75 CS2 (0.66 mm)
  • Obj. HC PL FLUOTAR L 40x/0.60 (3.3-1.9 mm)
  • Obj. HC PL APO 40x/1.30 Oil CS2 (0.24 mm)
  • Obj. HC PL APO 63x/1.40 OIL CS2 (0.14 mm)

Detectors

  • 1 x PMT Detector
  • 2 x HyD SP GaAsP Detector (sensitive)
  • Brightfield detector for DMI

Lasers

  • Laser 405 nm DMOD Compact
  • Laser Blue 488 nm
  • Laser Green 552 nm
  • Laser Red 638 nm

Camera

  • Leica DFC7000 GT monochrome camera