Nikon sora: Difference between revisions
Jump to navigation
Jump to search
Added technical specs |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Manuals and user guides == | |||
[[Nikon sora functions|What can it do?]] | [[Nikon sora functions|What can it do?]] | ||
Line 15: | Line 16: | ||
== Technical specifications == | == Technical specifications == | ||
=== Available hardware | === Available hardware === | ||
* 20x air obj. | * 20x air obj. | ||
Line 21: | Line 22: | ||
* 100x/1.49 oil (w.d. 160 um) | * 100x/1.49 oil (w.d. 160 um) | ||
=== Superresolution components | === Superresolution components === | ||
* SoRa spinning disc | * SoRa spinning disc | ||
Line 27: | Line 28: | ||
* 3D deconvolution software (in-line and parallel) | * 3D deconvolution software (in-line and parallel) | ||
=== Imaging lasers | === Imaging lasers === | ||
* 405 nm | * 405 nm | ||
Line 35: | Line 36: | ||
* 638 nm | * 638 nm | ||
=== Emission filters | === Emission filters === | ||
* UV | * UV | ||
Line 43: | Line 44: | ||
* Far-red | * Far-red | ||
=== Dual color simultaneous imaging | === Dual color simultaneous imaging === | ||
* blue/yellow (e.g. CFP / YFP) | * blue/yellow (e.g. CFP / YFP) | ||
* green/red (e.g. GFP / RFP) | * green/red (e.g. GFP / RFP) | ||
=== Software === | |||
* NIS-elements | |||
* Nikon batch-deconvolution | |||
=== Other === | |||
* FURA (calcium sensor) imaging filters and light source | |||
* "Tokai Hit" Stage-top live-cell incubation system (CO2, temperature and humidity control) | |||
FURA (calcium sensor) imaging filters and light source | |||
"Tokai Hit" Stage-top live-cell incubation system (CO2, temperature and humidity control) |
Latest revision as of 11:12, 29 September 2025
Manuals and user guides
How to switch to superresolution
Dual camera imaging wavelengths
Current status
The current status of the microscope can be found here and on the booking website.
Biosafety and access
The SoRa is located in an ML-1 room. See the Biosafety section on rules regarding working in this room, and how to get access.
Technical specifications
Available hardware
- 20x air obj.
- 40x/1.30 oil (working distance 200 um)
- 100x/1.49 oil (w.d. 160 um)
Superresolution components
- SoRa spinning disc
- Additional SoRa magnifiers 2.8x / 4.0x
- 3D deconvolution software (in-line and parallel)
Imaging lasers
- 405 nm
- 445 nm
- 488 nm
- 561 nm
- 638 nm
Emission filters
- UV
- Green
- Yellow
- Red
- Far-red
Dual color simultaneous imaging
- blue/yellow (e.g. CFP / YFP)
- green/red (e.g. GFP / RFP)
Software
- NIS-elements
- Nikon batch-deconvolution
Other
- FURA (calcium sensor) imaging filters and light source
- "Tokai Hit" Stage-top live-cell incubation system (CO2, temperature and humidity control)